Copyright © 2012, Max Machinery, Inc., Flow meter manufacturer and sales | Sitemap | (707) 433-2662 | 33A Healdsburg Ave, Healdsburg CA 95448 |
| 
(707) 433-2662 Request a quote
Model 295 Frequency
Output Signal: 5V
Output Resolution: 1000 pulses/rev
Linearization: linearized
Temperature rating: 105 or 155°C, 220 or 310°F
Model 295 Analog
Output Signal: ± 20mA or ± 10V
Output Resolution: 16 bit
Linearization: linearized
Temperature rating: 105 or 155°C, 220 or 310°F
Model 289 Inductive
Output Signal: 5V
Output Resolution: variable
Linearization: non-linearized
Temperature rating: 240°C, 465°F
The majority of Helical meters sold by Max use the Model 289 proximity pick-up to generate a pulse output. The attraction of the Model 289 is that it creates a pocket-less meter which is ideal for high viscosity materials. Due to the large installed base, Max Machinery will continue to offer the Model 289 as well as the new, 290 Series of linearized transmitters. If you are familiar with the Model 289 and wish to continue with it in your process, by all means specify it on future orders. If you would like to upgrade to either a higher resolution pulse signal, or a fully linearized analog signal, please review the Model 295 transmitter choices. If you have any questions as to which choice is the best fit for your project, feel free to give us a call at 707-433-2662 and we’ll be glad to help.