How does Max achieve high resolution?

Our signal processing approach really sets us apart. Instead of counting a gear tooth or rotor blade when it passes by, we continuously monitor an internal shaft position to determine flow meter rotational speed and direction. Our sensors detect rotation to within one one-hundredth of a degree, and coupled with the microprocessor’s “learning mode” technology and unique signal damping process, provides a useable output signal resolution 20 to 50 times larger than the competition. The payoff is increased measurement data for intermittent flow streams, low-flow rate measurements, and applications where accuracy is critical.