P234 Water Flow Meter

Measure low flows down to 1 cc/min of water and water-based chemicals in your dosing and injection applications. The Max P234 is compatible with RO antiscalants, defoamers, anti-corrosives, antiseptics, sterilization chemicals and many more.

Choose from frequency or analog transmitter options. Not for use in hazardous environments. Maximum temperature rating for all P234 transmitters is 90°C.

Category:
Flow 1 to 2000 cc/min
Port Size 1/4″ NPT or G 1/4-19 BSPP
Accuracy (at 1 cP) ± 0.4% of reading over a 100:1 range
Pressure 3000 psi (210 bar) maximum
K-Factor 180 pulses/cc
Fluids Water and most aqueous based chemicals and fluids in a pH range of 4 to 12

 

Specifications

MECHANICAL
Filtration
10 Micron recommended
Weight
4.1 kg (9.0 lbs)
MATERIALS OF CONSTRUCTION
External
Stainless Steel, type 316, type 304; Blue Xylan 316 fasteners
Wetted
Stainless Steel, type 316, Graphite; PEEK; Nickel Carbide
O-rings
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer
TRANSMITTER VARIATIONS
Signal Type
Output
Resolution (K-Factor)
Std. Temp†
High Temp†
Ultra Temp†
Frequency
5 VDC square wave (current sinking available)
180 pulses/cc
90°C
n/a
n/a
Frequency
5 VDC quadrature (2-phase)
90 pulses/cc/phase
90°C
n/a
n/a
Analog
0-10 VDC
Uni or Bi-directional
90°C
n/a
n/a
Analog
4-20 mA
Uni or Bi-directional
90°C
n/a
n/a
Compliance:
Not for use in hazardous environments. Adapting the meter to a conduit connection does not protect the system in a hazardous location. Do not use in a hazardous location as death or severe injury may occur.†Maximum temperature rating for all P234 transmitters is 90°C.

Applications

Downloads

DOWNLOADS MANUAL ANALOG SPEC SHEET FREQUENCY SPEC SHEET PN SELECTOR CALIBRATION EXAMPLE
P234 Water Flow Meter
PDF Icon PDF Icon PDF Icon PDF Icon PDF Icon

Drawings / Charts

P234 Dimensions

P234 PressureDropGraph
P234 PressureDropGraph

Product Selection Matrix

PSeriesWater PartNumber Selector 3000PSI Web Rev2022

Reviews

There are no reviews yet.

Be the first to review “P234 Water Flow Meter”

Your email address will not be published. Required fields are marked *

Related STEP Files

  • Step Files

    P234-INDUSTRIAL STEP File

    Rated 0 out of 5
    Free Download Add to cart
Scroll to Top